Stem Displacement
Reported version
3.0
Priority
P1 - High
Type
Functional
Frequency
Many
Severity
S4 - Minor
Reproducibility
Always
Status
closed
Regression
Yes
Workaround
No
Project
When the option "Small Stave" is on, note stems get displaced from their position. You can see it on the screshot attached
Attachment | Size |
---|---|
SmallTempTest.mscz | 20.77 KB |
Fix version
3.1.0
Comments
somewhat related to #282021: Beam thickness not scaling with staff size as that is also about small staves
Relates to #285228: [EPIC] Small staves issues
https://github.com/musescore/MuseScore/pull/4827
Fixed in branch master, commit 286a5285bb
fix #282026: scale stem displacement