Corruption after changing time signature
1. Open attached score (produced in 1.3).
2. Click on bar.
3. 'Add'>'Measures'>'Insert Measures...'.
4. Choose 2 measures.
5. 'OK'.
6. Drag 3/4 time signature to measure 2.
7. Drag 2/4 time signature to measure 3.
8. Drag 12/8 time signature to measure 3.
Result: Corruption (2 and a half beats, instead of 6).
Notes:
It is also reproducible in 2.0 nightly.
In the 1.3 score only, 9/8 time signature can be utilised in step 8 in reproducing corruption.
Using MuseScore 2.0 Nightly Build 0f25585 - Mac 10.7.5.
Attachment | Size |
---|---|
Corruption after changing time signature.mscz | 1.37 KB |
Corruption after changing time signature.png | 58.29 KB |
Comments
Hopefully someone will be able to improve the title and provide more details. :)
I just ran into what might be a simpler case of the same bug - or might be separate.
1) 4/4 score
2) add a single quarter note to any measure
3) drag 6/4 time signature to that measure
Result: measure is corrupt; only two beats.
If the following measure contains notes, they will be pulled into the measure to which the change was applied and broken up correct. but it appears we don't know how to break up a measure rest. Although it works just fine for 5/4.
Fixed in eacac5cedc
Automatically closed -- issue fixed for 2 weeks with no activity.