Better bar numbering - Both at start and at interval.

• Nov 14, 2018 - 03:15
Reported version
3.0
Priority
P2 - Medium
Type
Functional
Frequency
Once
Severity
S5 - Suggestion
Reproducibility
Always
Status
active
Regression
No
Workaround
No
Project

Bar numbering.
You can choose between Every system or At interval. I would like to se both options in use at the same time.
Example. I have a bar number at start of every line. But i would like there to also be bar numbers at every n'th measure. (a custom bar number placement would also be handy).


Comments

So you want "Every system" and "every x measures" not to be mutually exclusive, right?

What you can have right now already is in measure properties switch on and off the measure number, by changing the default of 'automatic' to 'always' or 'never'. Needs to be set on every individual measure (you want to deviate from default) though