Create a pickup measure in parts with two instruments at least leads to corruption and crash
2.0.3 version / Windows7
1) New score for Bb Clarinet and Flute (3/4 time signature)
2) Generate parts
3) Go in Bb Clarinet part (disable MM rests) -> right-click on the first measure -> Measure Properties -> Actual duration: 1/4 -> Ok
4) Go now in Flute part:
Result: the quarter rest expected is not showed
5) Enter three quarter notes in this part
Result: corruption
6) Undo three times (to remove the quarter notes)
7) View main score
Badly corruption (in particular, the empty second measure in flute staff )
8) Enter three quarter notes -> change the value, eg half note, of the third one
Result: crash
Comments
How is this different from #124966: Create a pickup measure in parts with two instruments at least causes a crash?
Does 68c8f68430 fix this issue here too?
The mentioned commit solves the problem for the 3.0 under development.
This issue is always active in the 2.0.3.
Ah, so there are 2 issues for 2 branches and still need a fix for 2.0.4, right?
Doesn't it make more sense to close this and reopen the other one, so that the same commit message ("fix #124966") will connect to it if merged for 2.0.4?
Yes that does make more sense.
Automatically closed -- issue fixed for 2 weeks with no activity.
Automatically closed -- issue fixed for 2 weeks with no activity.
Automatically closed -- issue fixed for 2 weeks with no activity.
Automatically closed -- issue fixed for 2 weeks with no activity.
Automatically closed -- issue fixed for 2 weeks with no activity.
Automatically closed -- issue fixed for 2 weeks with no activity.
Automatically closed -- issue fixed for 2 weeks with no activity.